ACCON NETLINK PRO COMPACT DRIVER



You have to adjust the transfer rate accon netlink pro compact well as the HSA of the automation system to be communicated with in the network-related settings. Because of this the initialization of a connection lasts a bit longer as online parameters have to be determined. Profibus configuration In principle it is the same as with the MPI configuration. But you have to remember that the net-related parameters are more voluminous.

ACCON NETLINK PRO COMPACT DRIVER DOWNLOAD

accon netlink pro compact You have to choose the profile which is used in the automation system. Bus parameters: Unlike the MPI bus profile the bus parameters with Profibus are not constant and change with the type and number of the used Profibus participants. You should always set the Profibus parameters which are used in the automation system. Figure Bus parameters To avoid these partly complex steps it is advantageous to use the autobaud function. This function determines the bus parameters automatically.

ACCON-NetLink-PRO Compact

accon netlink pro compact The switch is located in the hardware configuration of any Profibus interface. Figure Profibus, bus parameters PPI configuration The station address is the most important setting in connection with the bus configuration. The address must not be on the bus. The timeout value shows how long the communication drivers should try to establish a communication. Using network-related settings the transfer rate and the highest node address have to meet that of the automation system which is responded to.

Normally, the baud rate cannot be determined on PPI busses, automatically! From a user's view the bus systems only differ in the selectable transfer rates.

Simatic PLC S7 Adapters from Deltalogic – Industrial Control – European Automation Supplier

As well as in the additional options for Profibus. This function is not available for S systems. MPI Configuration The station address is the most important setting in connection with the bus configuration. If there is no response to a driver request within the set timeout accon netlink pro compact communication error will be sent to the Simatic application.

DRIVERS: ACCON NETLINK PRO COMPACT

When shortening the timeout you will neither get a reduction of the transmission time nor an increase of the data throughput, etc. You have to adjust the transfer rate as well as the HSA of the automation system to be communicated with in the network-related settings. Because of this the initialization of a connection lasts a bit longer as online parameters have to be determined. Profibus configuration In principle it is the same as with the MPI configuration. But you have to remember that the accon netlink pro compact parameters are more voluminous. You have to choose the profile which is used in the automation system. Bus parameters: Unlike the MPI bus profile the bus parameters with Profibus are not constant and change with the type and number of the used Profibus participants.

You should always set the Profibus parameters which are used in the automation system. Figure Bus parameters To avoid these partly complex steps it is advantageous to use the autobaud function. This function determines the bus parameters automatically. Produkte der Automatisierungstechnik.

Zur Kategorie Download. Zur Kategorie Ihre Karriere. Version 3.

Changes were made in setting access rights of installed files. At least firmware 2.

Please fill in all the required fields. An error occurred. Sie finden Informationen hierzu im Handbuch. Die Standard-Adresse ist 0, accon netlink pro compact Sie z.Der kompakte Alleskönner - unser meistverkaufter Kommunikationsadapter. The ACCON-NetLink-PRO compact is a handy communication and programming adapter between PC and S7 PLCs. It can access the S//